Utility and fire requirements for food carts
Key takeaways
Schedule a 15-minute appointment to discuss
- Sewer and stormwater - Connecting to City sewer? You'll need a grease interceptor and waste management systems. Discuss the requirements.
- Water - Connecting to City water? Discuss water supply and backflow prevention requirements.
- Plumbing permit application process - For questions about the plumbing permit application process? Discuss application setup and processing.
Wastewater and grease management
- Properties that host a food cart pod must provide dump stations for food cart wastewater that connect to the sanitary sewer.
- The on-site sanitary sewer disposal system must have a grease interceptor (gravity or hydromechanical).
- The grease interceptor must:
- Be approved for interior or exterior installation.
- Be easily accessible for inspection and grease removal.
- Include a sampling port if the unit is over 500 gallons.
- Be vented (see venting requirements below).
- Be sized based on the total number of carts and their drainage fixture units (DFUs).
- Meet the Oregon Plumbing Specialty Code (OPSC) Section 1014.0.
- Human waste cannot be directed to the grease interceptor.
- The grease interceptor must:
- Class 3 and 4 food carts typically need a hand sink and a three-compartment sink.
Graywater drainage and venting requirements
- You must install one greywater dump station for every four food carts.
- The dump stations must be hydraulically isolated through grading, berms, or an elevated standpipe with a lid to prevent stormwater runoff.
- Drain hoses from food carts must connect indirectly to the drainage standpipe receptor.
- Each drainage standpipe receptor must:
- Have a self-closing cap (RV-type or other approved).
- Be trapped.
- Use a minimum 3-inch diameter pipe.
- Serve no more than four carts per standpipe.
- Drainage piping, branch sizing, and materials must follow the current OPSC.
- Venting is required for all grease interceptors and drainage piping.
- Vents must be at least 3 feet from property lines.
- Vents must extend at least 10 feet above ground.
Resources:
- Prevent Pollution from Food Cart Wastewater: How to connect a food cart or cart pod to Portland's sewer system
- Food Cart Pods Chapter 6.2 of the BES Source Control Manual (2020)
- Food Cart Pods | Multnomah County
Water supply and backflow prevention requirements
- Each food cart must have a potable water supply.
- The supply must use a self-draining sanitary yard hydrant or other approved plumbing code connection.
- The Portland Water Bureau may require a Premise-Isolation Reduced Pressure Backflow Assembly (RPBA) to be installed on the water service.
Plumbing permits and fixtures
- Food cart pods: All plumbing work requires a plumbing permit and inspection.
- Individual food carts: Plumbing work that connects to the City water or sewer requires a plumbing permit and inspection.
- All work must follow the current Oregon Plumbing Specialty Code (OPSC).
- Permitted plumbing fixtures include:
- Trap standpipe riser receptors
- Grease interceptors
- Floor drains
- Catch basins
- Sanitary yard hydrants
- RP devices
- Drinking fountains
- Outdoor sinks
- Bathroom fixtures
- Any other plumbing fixtures installed in the pod
Trash enclosure requirements
Cover
- The waste storage area must have a structural cover that fully shields it from rain.
- The cover must extend far enough to keep stormwater out of the hydraulically isolated area.
Pavement
- The ground under the trash and recycling area must be paved with asphalt or concrete.
Drainage
- The waste storage area must be protected from stormwater flowing in and wastewater flowing out.
- Use berms or grading to create hydraulic isolation.
- Drainage from this area must be connected to a sanitary sewer line, with a drain located inside the isolated area.
Containment
- Any liquids stored in the waste area must be contained in secondary containment to prevent spills or leaks.
- Recyclable cooking grease must also be stored with secondary containment.
- Acceptable containment methods include a curb, berm, spill pallet, or other approved system.
- The containment must hold at least 110% of the largest container's volume, or 10% of the total volume of all containers—whichever is greater.
Resource: Waste Storage Chapter 6.1 of the BES Source Control Manual (2020).
Fire safety requirements
Get propane, fire suppression, exiting, and other fire safety requirements for food carts.
Permit considerations
- An approved Building Permit or Development Review Permit is required before a Plumbing Trade Permit can be approved.
- The Bureau of Environmental Services (BES) will review for:
- Fats, oils, and grease (FOG)
- Trash storage
- Sewer Connections
- Stormwater Management
- System Development Charges (SDCs) apply.
- Food cart pods must follow Chapters 6.1 and 6.2 of the BES Source Control Manual (2020).
- Plans to include with your development permit application:
- Site plan showing:
- Food cart locations
- Utilities
- Trash and recycling storage areas
- Source control compliance plan showing:
- Conveyance piping and connections
- Grease interceptor - Location and size
- Graywater dump stations
- Trash and recycling storage areas
- Get the full list of plan requirements.
- Site plan showing:
Plumbing permit plan review
- A mandatory plumbing plan review is not required for food cart pods under OAR 918-780-0040.
- You may request a voluntary plumbing plan review.
- Fees are the same as a mandatory plan review.
- Reviews are completed for plumbing code compliance under the current State of Oregon Plumbing Specialty Code.
- Approved plumbing plans and manufacturer installation instructions must be available on-site during inspection.